Skip to content

TPS 07A

micro-focus protein crystallography (rotation MX) on an Arinax MD3 + DECTRIS EIGER2 X 16M with an ISARA robot; reuses the i03 / MX3 Goniometer and MX Methods, novelty is the Site and its Blu-Ice/DCSS-over-EPICS orchestration seam (the 2-BM pattern, confirmed live over MXCuBE).

Property Value
Facility NSRRC (EPICS (Blu-Ice / DCSS))
Sector 07a
Source insertion-device
Modelled reverse-engineered, full coverage

Generated from the descriptor

This page is generated from the descriptor at deployments/tps-07a/beamline.yaml. Edit the descriptor, not this page.

The device handles are read from the facility's public controls configuration and verified against it; vendor parts, energies, and physical positions are not in it and are carried confirm until beamline staff verify them. Source: light911/NSRRC_TPS07A.

Enclosures

Enclosure Role Facility Permit signal
TPS-07A-OH optics-hutch nsrrc confirm: PSS permit leaf not in public source; the optics hutch carries the DCM and beam-conditioning optics (PSS-1, ENC-1)
TPS-07A-EH experiment-hutch nsrrc confirm: PSS permit leaf not in public source; the experiment hutch carries the MD3 microdiffractometer, the EIGER2, and the ISARA robot (PSS-1, ENC-1)

The beamline

NSRRC's Taiwan MX beamline: micro-focus macromolecular crystallography on a single EPICS floor with a Blu-Ice / DCSS orchestration layer CORA's edge would replace, the 2-BM seam rather than the MX3 seam.

  • Source: the beam, produced and conditioned before the sample.
  • Sample: the sample environment and its positioning.
  • Detector: what records the beam after the sample.
  • Controls: the control plane CORA's edge conducts over.

More