Skip to content

Sample

Rasor

The RASOR endstation: a soft X-ray scattering diffractometer with a polarization-analysis arm, a cryostat sample stage, and the counting detectors.

Enclosure: i10-rasor.

Note

The sample circles bind the catalog Goniometer, with a reciprocal-space PseudoAxis over them (the 4-ID / 8-ID / i06-1 diffractometer pattern; the Assembly is named, not built, DIFF-1). The polarization-analysis arm binds the catalog PolarizationAnalyzer (graduated on the rule-of-three across 4-ID, i10, ID32, P09; POL-2). Detection is point / current-integrating: no area detector exists, so the scattered-beam point detector and the monitor / fluorescence / drain-current channels bind FluxMonitor (DET-1).

Name Family PV Key specs Replaceable Status
Diffractometer Goniometer ME01D-MO-DIFF-01: RASOR sample diffractometer (two-theta scattering arm TWOTHETA, sample theta / chi, chamber X, alpha); the circle roles and the Assembly(Diffractometer) binding are DIFF-1 new confirm
ReciprocalSpace PseudoAxis confirm: reciprocal-space virtual axis over the RASOR circles; the inverse-kinematics partition rule is deferred as on 4-ID / 8-ID / i06-1 (DIFF-2) reciprocal-space pseudo-axis over the diffractometer (DIFF-2) new confirm
AnalyzerArm PolarizationAnalyzer ME01D-MO-POLAN-01: the polarization-analysis arm (POLAN: analyzer two-theta / theta, py / pz, eta) carrying the analyzer crystal; binds the catalog PolarizationAnalyzer Family (POL-2). dodal exposes the motors only; the analyzer crystal is implicit hardware (POL-2) new confirm
DetectorSlit Slit ME01D-MO-APTR-0 the detector slits in front of the RASOR point detector (APTR-01 / APTR-02) new confirm
Pinhole Aperture ME01D-EA-PINH-01: the endstation beam-defining pinhole on its XY stage; Aperture-vs-stage is STAGE-1 new confirm
SampleStage LinearStage ME01D-MO-CRYO-01: the cryostat sample-positioning stage (x / y / z); plain in-air translation, not a UHV manipulator (STAGE-1) new confirm
SampleTemperatureController TemperatureController ME01D-EA-TCTRL-01: Lakeshore 340 cryostat sample temperature controller; reuses the graduated Family (presents Regulator); range is TEMP-1 new confirm
FocusingMirror Mirror BL10I-OP-FOCS-01: the RASOR-branch focusing mirror (piezo collimating mirror) new confirm
Detector FluxMonitor scaler: ME01D-EA-SCLR-01:SCALER1
amplifiers: ME01D-EA-IAMP-01..06:
the RASOR counting detection: the scattered-beam point detector (current-amp + Struck scaler, channel S18), the incident-flux monitor (S17), and the fluorescence (S19) and drain-current / total-electron-yield (S20) channels, through Femto / SR570 amplifiers; no area detector exists, so the science detector binds FluxMonitor (DET-1) new confirm

Magnet endstation

The i10-1 / I10J endstation: X-ray magnetic dichroism with the sample in an applied magnetic field, at low temperature.

Enclosure: i10-1.

Note

The electromagnet and the superconducting field-sweep magnet both bind the catalog Magnet Family (graduated; presents Regulator; one family, the fly / sweep capability is a per-Asset affordance, not a split; MAG-1). The magnet sample stages bind LinearStage, the Lakeshore binds TemperatureController, and the counting chains (TEY / FY / diode / monitor) bind FluxMonitor (DET-1).

Name Family PV Key specs Replaceable Status
Electromagnet Magnet BL10J-EA-MAGC-01: the i10-1 electromagnet (set-and-read field); binds the catalog Magnet Family (graduated; a consumer after 4-ID, MAG-1) new confirm
HighFieldMagnet Magnet BL10J-EA-SMC-01: the i10-1 superconducting high-field magnet (Flyable field-sweep); the same catalog Magnet Family as the electromagnet, the sweep capability is a per-Asset bound-Model affordance (MAG-1) new confirm
HighFieldMagnetStage LinearStage BL10J-EA-MAG-01: the high-field-magnet sample stage (x / y / pitch) new confirm
ElectromagnetStage LinearStage BL10J-MO-CRYO-01: the electromagnet cryostat sample stage; cryostat motion folds into the stage Asset (MAG-1 for the low-temperature environment) new confirm
MagnetTemperatureController TemperatureController BL10J-EA-TCTRL-41: Lakeshore 336 sample temperature controller at i10-1; reuses the graduated Family (presents Regulator); range is TEMP-1 new confirm
MagnetSlit Slit BL10J-AL-SLITS- the i10-1 branch beam-defining slits new confirm
MagnetFocusingMirror Mirror BL10J-OP-FOCA-01: the i10-1-branch focusing mirror new confirm
MagnetDetector FluxMonitor scaler: BL10J-EA-SCLR-01..02:
amplifiers: BL10J-EA-IAMP-01..06: / BL10J-DI-IAMP-07..09:
the i10-1 counting detection: the total-electron-yield (TEY), fluorescence-yield (FY), diode, and incident-monitor channels through Femto / SR570 amplifiers and the I10J scaler cards; no area detector, point / current-integrating XMCD detection (DET-1) new confirm