P11

high-throughput macromolecular crystallography (rotation MX) and bio-imaging on a goniometer + Pilatus detector with cryostream cooling; PETRA III's first MX beamline, a reuse-and-reinforce deployment coining no new vocabulary (reuses the i03 MX vocabulary and the pending mx_data_collection / tomography Methods); a sparse registry, so the experiment hutch is modelled as grouped stages with the goniometer carried as a question.

Property Value
Facility PETRA III (Tango / Sardana)
Sector P11
Source insertion-device
Modelled reverse-engineered, full coverage

Generated from the descriptor

This page is generated from the descriptor at deployments/p11/beamline.yaml. Edit the descriptor, not this page.

The device handles are read from the facility's public controls configuration and verified against it; vendor parts, energies, and physical positions are not in it and are carried confirm until beamline staff verify them. Source: python-nxstools-extras-p11.

Enclosures

Enclosure Role Facility Permit signal
p11-oh optics-hutch petra-iii confirm: DESY PSS permit signal for the P11 optics hutch; not in the OnlineXML (PSS-1)
p11-eh experiment-hutch petra-iii confirm: DESY PSS permit signal for the P11 experiment hutch; not in the OnlineXML (PSS-1)

The beamline

Macromolecular crystallography: rotation MX on a micro-goniometer and area detector with an automated sample changer, reusing the fleet MX vocabulary.

  • Source: the beam, produced and conditioned before the sample.
  • Sample: the sample environment and its positioning.
  • Detector: what records the beam after the sample.
  • Controls: the control plane CORA's edge conducts over.

More