P11¶
high-throughput macromolecular crystallography (rotation MX) and bio-imaging on a goniometer + Pilatus detector with cryostream cooling; PETRA III's first MX beamline, a reuse-and-reinforce deployment coining no new vocabulary (reuses the i03 MX vocabulary and the pending mx_data_collection / tomography Methods); a sparse registry, so the experiment hutch is modelled as grouped stages with the goniometer carried as a question.
| Property | Value |
|---|---|
| Facility | PETRA III (Tango / Sardana) |
| Sector | P11 |
| Source | insertion-device |
| Modelled | reverse-engineered, full coverage |
Generated from the descriptor
This page is generated from the descriptor at deployments/p11/beamline.yaml. Edit the descriptor, not this page.
The device handles are read from the facility's public controls configuration and verified against it; vendor parts, energies, and physical positions are not in it and are carried confirm until beamline staff verify them. Source: python-nxstools-extras-p11.
Enclosures¶
| Enclosure | Role | Facility | Permit signal |
|---|---|---|---|
p11-oh |
optics-hutch | petra-iii |
confirm: DESY PSS permit signal for the P11 optics hutch; not in the OnlineXML (PSS-1) |
p11-eh |
experiment-hutch | petra-iii |
confirm: DESY PSS permit signal for the P11 experiment hutch; not in the OnlineXML (PSS-1) |
The beamline¶
Macromolecular crystallography: rotation MX on a micro-goniometer and area detector with an automated sample changer, reusing the fleet MX vocabulary.
- Source: the beam, produced and conditioned before the sample.
- Sample: the sample environment and its positioning.
- Detector: what records the beam after the sample.
- Controls: the control plane CORA's edge conducts over.
More¶
- Techniques: what the beamline is for.
- Governance: who acts, and the trust shape that gates them.
- Open questions: the world-facts CORA needs staff to confirm.