Techniques

What CORA would run at FMX: macromolecular crystallography, each a Catalog Method. FMX is CORA's second MX beamline (after Diamond i03) and follows the same Method-deferral discipline.

FMX's science is protein crystallography: rotate a cryo-cooled crystal in a focused microbeam and read the diffraction on the Eiger, locate crystals with fast grid scans, and exchange samples with a robot. These are the MX Methods i03 brought to CORA; FMX is their second consumer. The Methods below render unlinked and stay pending until the owner-scope decision (TECH-1) brings them into the catalog.

Technique Beam Detector Status in CORA
Rotation (oscillation) data collection monochromatic, microfocused AreaDetector (Eiger, Detector Role) the i03 mx_data_collection Method binding Goniometer + Eiger + vector + Zebra, pending; 2nd consumer (TECH-1)
Grid scan / sample location monochromatic, microfocused AreaDetector + SampleCamera the i03 grid_scan Method over the Zebra-triggered goniometer raster, pending; 2nd consumer (TECH-1)
Autonomous sample exchange n/a n/a the i03 sample_exchange Method: a Procedure over the spine + a Subject custody thread, pending; 2nd consumer (ROBOT-1)
Anomalous element ID (fluorescence) monochromatic, energy-swept FluorescenceDetector (Mercury, Sensor) the edge scan picks the energy for SAD / MAD; reuses the energy axis (DET-1)
Fixed-target serial (chip) monochromatic, microfocused AreaDetector the chip-scanner raster; reuses the serial_crystallography Method (i24 / LCLS-MFX), deferred (SERIAL-1)

Why the Methods stay pending

FMX reuses the three MX Methods Diamond i03 left pending. Unlike a loose device Family (which a second sighting promotes on a mechanical rule-of-three, as ISS did for the emission spectrometer), a pending Method has no automatic promotion: it is coined by deliberate decision when a conduct-path needs it, the same discipline that keeps energy_scan deferred even across several consumers. FMX makes each of mx_data_collection, grid_scan, and sample_exchange a two-consumer Method (i03 + FMX), which strengthens the eventual case to coin them but does not force it in a descriptor scaffold (TECH-1). The device Roles already exist (the graduated Goniometer presents Positioner, the Eiger presents Detector), so what is pending is the recipe, not a device shape.

The autonomous sample-exchange loop is the genuinely non-obvious modelling: the unattended sequence (load pin, centre, collect, unmount, next) is a Procedure over the spine, threaded through the Subject custody lifecycle (Received to mounted to measured to Returned) and gated by a Clearance issued after a safety review. The robot itself is just a Positioner Asset; the workflow is the modelling (ROBOT-1). The per-experiment recipes (oscillation ranges, exposure, grid parameters, the exchange sequence) are calibration the deployment must supply.