MANACA

macromolecular crystallography (rotation MX, serial and room-temperature) on a goniometer + area detector with a 48-pin sample changer; Sirius's first MX beamline, reuses the i03 / FMX / AMX / MX3 Goniometer and MX Methods on the EPICS floor + MXCuBE3, no new Family.

Property Value
Facility Sirius (EPICS + MXCuBE3)
Sector MANACA
Source insertion-device
Modelled reverse-engineered, full coverage

Generated from the descriptor

This page is generated from the descriptor at deployments/manaca/beamline.yaml. Edit the descriptor, not this page.

The device families are inferred from public facility pages and papers; no control handles or vendor models are public, so every value is carried confirm until staff verify it. Source: lnls.cnpem.br facility page.

Enclosures

Enclosure Role Facility Permit signal
manaca-optics optics-hutch sirius confirm: Sirius PSS permit leaf not published per beamline (PSS-1, ENC-1)
manaca-experiment experiment-hutch sirius confirm: Sirius PSS permit leaf not published; the experiment hutch carries the goniometer, the detector, and the sample changer (PSS-1, ENC-1)

The beamline

Sirius's first macromolecular-crystallography beamline: rotation MX on a goniometer and area detector with a 48-pin sample changer, reusing the fleet MX vocabulary on the Sirius EPICS floor.

  • Source: the beam, produced and conditioned before the sample.
  • Sample: the sample environment and its positioning.
  • Detector: what records the beam after the sample.
  • Controls: the control plane CORA's edge conducts over.