The developer's by-kind index: where each CORA aggregate's ID19 content lives, why this BLISS-floor imaging deployment coins no new family, and the record of what is deliberately deferred. Design-phase scaffold.

For the aggregate shapes see the architecture model and the per-BC modules.

Aggregate (BC) Where at ID19
Asset (Equipment) the stage pages: Source, Sample
Capability, Method (Recipe) Techniques
Enclosure (Enclosure) the index
Zone, Conduit, Policy (Trust); Actor (Access) Governance
Procedure, Recipe, Caution, Supply, Subject, Run, Campaign, Dataset, Decision deferred (design-phase; see below)

What makes ID19 new

ID19 is CORA's first imaging beamline on a non-EPICS control floor. Most of the fleet is EPICS (APS, Diamond, NSLS-II, SLAC, all ophyd / bluesky / dodal / pcdshub). ESRF runs BLISS, a Tango-based control system; its soft X-ray sibling ID32 opened the BLISS floor for CORA, and ID19 is the first to bring it to tomographic imaging. That is the novelty, and it is a control-plane concern, not a device or technique concern.

The seam model that today reads "EPICS is the floor" generalizes at ID19 to "BLISS / Tango is the floor". CORA's edge conducts the tomographic scan over its ControlPort against BLISS scan procedures and Lima detector servers, rather than EPICS IOCs. The test ID19 poses is that the ControlPort and the conduct-versus-drive-through seam are genuinely control-system-agnostic, not secretly EPICS-shaped (see Controls, CTRL-1).

No new families, no new methods

ID19 is a microtomography beamline, and CORA already models microtomography. So holding the device families and the technique constant is deliberate: it isolates the control-plane axis as the only new thing.

  • The rotation stages bind the catalog RotaryStage. mrsrot (MR) and hrsrot (HR) are the tomographic spins, the master motions of each scan, expected to clock the detector triggering (SAMPLE-1).
  • The sample and detector positioning stages bind the catalog LinearStage. Sample centring (with the XYOnRotation pseudo-axis keeping the sample on the rotation axis) and the detector propagation distance are plain linear motion (SAMPLE-1, DET-1).
  • The detectors bind the catalog Camera, which presents the Detector Role. ID19's indirect-detection area detectors (interchangeable Frelon CCD, PCO 4k, PCO Dimax high-speed, and Basler Lima cameras) are thin Camera instances (DET-1).
  • The optics bind existing Families. Monochromator (the TripleMono), Slit (primary / secondary), Transfocator (the white-beam Be-lens transfocator), Filter (the attenuator banks, folding in per the i03 precedent rather than a new Attenuator Family), Shutter (front-end and beam shutters), and InsertionDevice (the undulator / wiggler set).
  • The technique is the existing tomography Method. ID19 is a further consumer of the Method the 2-BM pilot and TomoWise carry; the Practice ID19_microtomography_practice is carried pending only because ID19 is not yet driven by CORA (TECH-1).

ID19 coins no new Family, nothing graduates, and the catalog is unchanged.

Two endstations

MR (micro-resolution) and HR (high-resolution) are distinct BLISS sessions (MRTOMO, HRTOMO) sharing the source and optics. CORA models each as its own sample and detection group under the shared experiment hutch: same Families, same tomography Method, different stage stack and magnification optic. This is a Practice-and-settings difference, not new vocabulary.

Deliberately not here yet

  • The further endstations (ENDSTATION-1). The config carries MH, MED, laminography (LATOMO, a MicosAnka-over-TCP controller with a tilt-transformation pusher), RADIO, PCOTOMO, the SmarAct multi-tower stack, and the FalconX / Mercury fluorescence MCAs. This cut models MR and HR, the two main tomography stations; the rest are noted, not modelled.
  • The PSS permit signals (PSS-1). The TangoShutter handles (frontend, id19/bsh/1, id19/bsh/2) are known, but the personnel-safety permit signals behind them are not in the config; carried pending, not invented.
  • Vendor models, serials, and physical positions. Not in the config; carried confirm.
  • The simulated devices and full asset-tree scenarios. No test_id19_*.py registers the asset tree, and no vendor Models are bound.
  • Operations and experiment views. A runbook and live experiment view for a beamline CORA does not yet drive would be invention; see the note on the index.