Skip to content

Sample

Endstation

The coherence-branch endstation: the piezo sample-scanning stage, the side viewing camera, and the Merlin coherent-diffraction area detector.

Enclosure: i13-1.

Note

All reuse existing catalog Families. The piezo sample-scanning stage binds LinearStage (the ptychography raster is its operative motion; the fixed-angle lab-frame variant is a setting on the same stage, SAMPLE-1). The Merlin photon-counting detector and the side viewing camera bind Camera (DET-1). The coherent lensless-imaging acquisition is a Method, not a device (TECH-1).

Name Family PV Key specs Replaceable Status
SampleStage LinearStage BL13J-MO-PI-02: the PI piezo sample-scanning stage (x / y / z); the ptychography raster motion; a fixed-angle lab-frame variant is on BL13J-MO-PI-02:FIXANG: as a setting on the same stage (SAMPLE-1) new confirm
SideCamera Camera BL13J-OP-FLOAT-03: the side viewing camera (an Aravis / GenICam optical camera) for sample alignment (DET-1) new confirm
Detector Camera BL13J-EA-DET-04: the Merlin (Medipix3) photon-counting area detector recording the far-field coherent-diffraction pattern; the science detector for ptychography / CDI (DET-1) new confirm