P21¶
Swedish Materials Science high-energy diffraction (P21.2) and total scattering / PDF (P21.1) across an optics hutch, an EH3 endstation, and a LAB station; a thin reuse-and-reinforce scaffold (grouped motor banks, detectors carried pending), reusing the pending diffraction / total_scattering Methods.
| Property | Value |
|---|---|
| Facility | PETRA III (Tango / Sardana) |
| Sector | P21 |
| Source | insertion-device |
| Modelled | reverse-engineered, full coverage |
Generated from the descriptor
This page is generated from the descriptor at deployments/p21/beamline.yaml. Edit the descriptor, not this page.
The device handles are read from the facility's public controls configuration and verified against it; vendor parts, energies, and physical positions are not in it and are carried confirm until beamline staff verify them. Source: python-nxstools-extras-p21.
Enclosures¶
| Enclosure | Role | Facility | Permit signal |
|---|---|---|---|
p21-oh |
optics-hutch | petra-iii |
confirm: DESY PSS permit signal for the P21.2 optics hutch; not in the OnlineXML (PSS-1) |
p21-eh3 |
experiment-hutch | petra-iii |
confirm: DESY PSS permit signal for the EH3 experiment endstation; not in the OnlineXML (PSS-1) |
p21-lab |
experiment-hutch | petra-iii |
confirm: DESY PSS permit signal for the LAB station; not in the OnlineXML (PSS-1) |
The beamline¶
High-energy X-ray diffraction (Swedish Materials Science, P21.1 / P21.2): powder and single-crystal diffraction of bulk and engineering samples across several stations.
- Source: the beam, produced and conditioned before the sample.
- Sample: the sample environment and its positioning.
- Detector: what records the beam after the sample.
- Controls: the control plane CORA's edge conducts over.
More¶
- Techniques: what the beamline is for.
- Governance: who acts, and the trust shape that gates them.
- Open questions: the world-facts CORA needs staff to confirm.