Sample¶
The sample manipulators for the soft (RSoXS, SST-1) and tender (HAXPES, SST-2) endstations, and the sample-environment thermal control. This stage spans both branches; the enclosure tag is the soft branch, and each device note states its branch. PVs verified against the RSoXS and HAXPES TOML device manifests.
Enclosure: SST-1.
Note
SST holds samples in UHV manipulators in each endstation: a four-axis solid-sample stage for RSoXS soft-scattering, and a multi-axis manipulator for HAXPES photoemission. Both reuse the Manipulator family (graduated by ESM). The Linkam / Lakeshore thermal control reuses TemperatureController. A NEXAFS manipulator and the in-situ accessories (a flood gun, a source-measure unit, a syringe pump, an ADR cryostat) are deferred (INSITU-1).
| Name | Family | PV | Key specs | Replaceable | Status |
|---|---|---|---|---|---|
RSoXSManipulator |
Manipulator |
XF:07ID2-ES1{Stg-Ax: |
RSoXS soft-scattering solid-sample manipulator (X / Y / Z / Yaw, the primary sample holder). Reuses the Manipulator family (graduated by ESM). | confirm |
|
HAXPESManipulator |
Manipulator |
XF:07ID1-BI{HAX-Ax: |
HAXPES photoemission sample manipulator (X / Y / Z / R) in the SST-2 tender branch (its PV sits under the XF:07ID1-BI zone label, a source naming quirk, not the tender DCM's 07ID6 zone). Reuses the Manipulator family (graduated by ESM). The NEXAFS endstation has its own manipulator (XF:07ID1-BI{NXFS-Ax:), deferred. | confirm |
|
SampleTemperature |
TemperatureController |
XF:07ID2-ES1{TCtrl:1}LS336: |
Sample-environment thermal control (a Lakeshore 336). Reuses the TemperatureController family (graduated #350). Which units are live per endstation is TEMP-1. | confirm |