Skip to content

Sample

Xmcd

The XMCD endstation: a 9 Tesla split-coil high-field magnet with a variable-temperature insert (VTI), an X-ray emission (XES) spectrometer arm, and the Andor CCD.

Enclosure: id32-xmcd.

Note

The 9 T XMCD magnet binds the catalog Magnet Family (graduated; the third consumer after 4-ID + i10-1, MAG-1). The VTI sample-temperature and the coil / shield diagnostics bind TemperatureController (the LakeShore precedent). The XES arm binds the catalog SpectrometerArm Family (the second arm that completed the rule-of-three; graduated). The CCD binds Camera; the sample stage binds LinearStage.

Name Family PV Key specs Replaceable Status
Magnet Magnet tango://id32/cryogenic_magnet_ps/xmcd1 (CryogenicPSController); serial tango://id32/Serialrp_232/lid323_ttyR33 the 9 T / 4 T split-coil superconducting XMCD magnet: 9.02 T coil + 4.05 T coil, one field setpoint axis (the field reads as a settable axis, presenting the Regulator Role). Binds the catalog Magnet Family (graduated; the third consumer after 4-ID + i10-1, MAG-1) new confirm
SampleTemperatureController TemperatureController tango://id32/regulation/ls336_hfm_* (LakeShore 336; GPIB gpibid32b pad 11) the VTI sample-temperature LakeShore 336 (inputs hexapod / helium-pot / sample, two control loops); the He needle valve / VTI flow folds into this cryostat regulation (TEMP-1) new confirm
CryostatDiagnostics TemperatureController tango://id32/regulation/ls340_hfm_* (LakeShore 340; GPIB gpibid32b pad 12) the magnet-cryostat diagnostic LakeShore 340 (the superconducting-coil, shield, and helium-reservoir temperatures); a second Regulator instance monitoring the magnet plant (TEMP-1) new confirm
XesSpectrometerArm SpectrometerArm BLISS xes_spectro (SpectrometerArmsController); IcePAP iceid329: xesdetx/xesdetz, xesgrtx/xesgrty, xesgrot, xesmask the XES (X-ray emission) Rowland-geometry spectrometer arm (xes_spectro): real axes xesdetx/xesdetz/xesgrtx -> virtual radii xesr1/xesr2; grating mode XES_1200 (radius 26055, xesgrot). The SAME SpectrometerArmsController class as the RIXS arm, the second instance that made the rule-of-three; binds the graduated catalog SpectrometerArm Family new confirm
XesDetector Camera tango://id32/limaccds/andor_2 (Lima) the Andor CCD at the XES / XMCD endstation; reuses Camera (DET-1) new confirm
SampleStage LinearStage confirm: the XMCD sample-positioning stage inside the magnet VTI; the axis set and handles are SAMPLE-1 the XMCD sample-positioning stage in the magnet bore (SAMPLE-1) new confirm