The sample-scanning side. PVs verified against dodal src/dodal/beamlines/i13_1.py, carried confirm.

I13-1 raster-scans a coherent beam across the sample and reconstructs a real-space image from the far-field diffraction it records (ptychography / CDI). On this side that means one thing: a stage that drives the raster. The dodal coherence-branch module exposes the sample stage and the two cameras, and nothing of the shared I13 source and optics upstream (SRC-1, OPT-1), so this page is the sample side only.

Asset Family PV What it does
SampleStage LinearStage BL13J-MO-PI-02: rasters the sample across the coherent beam (the ptychography scan)

The sample stage

The SampleStage is a PI piezo sample-scanning stage. Its operative motion is the ptychography raster: the scan trajectory that steps the sample through the coherent beam while the detector records a far-field diffraction pattern at each point. CORA binds it to the catalog LinearStage family; it carries the PVs confirm and tracks the stage's live status and full axis set as SAMPLE-1.

The same stage also carries a fixed-angle lab-frame variant (BL13J-MO-PI-02:FIXANG:). This is a setting on the one stage, not a second Asset: the same SAMPLE-1 hardware, addressed in a lab-frame fixed-angle configuration. It is noted here so the reader knows the two PV faces are one stage (SAMPLE-1).

Why no new family here

The scout anticipated a "coherent imaging device family" for I13-1. That is the wrong axis. The novelty at a ptychography / CDI beamline is not a kind of device; it is an acquisition shape plus a reconstruction: raster the coherent beam, capture the far-field diffraction, and invert the diffraction stack into a real-space image. That belongs to a Method, not to a device class.

So the devices stay plain. The stage is a LinearStage, the side camera and the Merlin detector are Cameras, and no family graduates. Ptychography / CDI is carried as a new pending Method (the fleet's first coherent diffractive imaging), TECH-1; the image reconstruction from the diffraction stack is ComputePort work, not a beamline device. The full deployment-level reasoning is on the model page.

The honest caveat is the partial scope: the shared I13 source and optics (the undulator, monochromator, and mirrors that condition the coherent beam this stage scans through) are absent from the dodal module and deferred, not invented (SRC-1, OPT-1). An in-situ sample environment, if I13-1 runs one, is likewise not in the module and left to a later cut. The beamline source-walk and the inventory carry the flat reference.